Fire shutters over the conveyor lines in Alconbury

A distribution facility in Alconbury, Cambridgeshire needed fire-rated protection where its conveyor lines pass through internal fire compartments. Avanti Doors supplied and installed a run of 60-minute fire-rated roller shutters over the conveyor openings, integrated with the site's fire-alarm system so they close automatically in a fire event. Completed in May 2026.

Installed
May 2026
Location
Alconbury, Cambridgeshire
System
60-min fire-rated roller shutters (EN1634-1 / EN16034)

On site

Watch a shutter in action

Filmed on site — one of the fire shutters running through its closing cycle over a conveyor line.

Scope of works

Certified fire protection across the conveyor line

What we supplied and installed

  • 60-minute fire-rated electrically-operated roller shutters over the conveyor pass-throughs
  • Certified to EN13241, EN1634-1 and EN16034 with mandatory UKCA marking
  • Single-phase tubular motors, 50mm solid-lath curtains, full hoods, 65mm guides and T-section bottom rails
  • Safety brake, battery back-up and key-switch override on each unit, finished in a painted RAL
  • Sealed with fire-retardant mastic and linked to the fire-alarm system — 30-second delay with automatic reset
  • Limits set, fire panel configured, tested on completion and left in full working order

Why it matters for the site

  • Keeps conveyor openings compartmented so fire can't travel the line between zones
  • Shutters close automatically on a fire signal, with a timed delay so the conveyor can clear
  • Fire-rated to 60 minutes and UKCA-certified for compliance sign-off
  • Battery back-up keeps the safety function live even if mains power is lost

How it was done

The installation process

  1. 1Openings surveyed around the conveyor runs and the site's fire-compartment lines.
  2. 2Fire-rated roller shutters supplied and installed over each conveyor pass-through.
  3. 3Sealed with fire-retardant mastic, limits set and each shutter linked to the fire-alarm panel.
  4. 4Programmed to a 30-second delay with automatic reset, tested and left in full working order.

The outcome

Results & benefits

Fire-rated roller shutters live over the conveyor lines.

Automatic closure on a fire signal, timed so the line can clear first.

60-minute fire rating, UKCA-marked for compliance.

Completed in May 2026 at a Cambridgeshire distribution facility.

Fire-rated roller shutters over the conveyor lines at a Cambridgeshire distribution facility

Need fire shutters?

Plan fire shutters for your site

From conveyor pass-throughs to loading bays and internal openings, we supply, install and maintain fire-rated roller shutters — certified, alarm-integrated and set up to protect your fire compartments.

  • Fire-shutter proof
  • Fire-rated roller shutters live over the conveyor lines.
  • Automatic closure on a fire signal, timed so the line can clear first.
  • 60-minute fire rating, UKCA-marked for compliance.